What is the difference between the Fastpette V2 and the Fastpette Pro?

The Fastpette V2 and Fastpette Pro function the same way. Both units are compatible with the same filters and tubes. They also have the same speed and dispensing modes. The Fastpette Pro has a LCD display that shows the units battery life, set speed, and mode. The V2 does not have a display. It uses

Read More… from What is the difference between the Fastpette V2 and the Fastpette Pro?

Transferpette Adjustment Knob Installation, Item # BT 9481

Transferpette Adjustment Knob Installation: Link to product page: BT 9481 Take micrometer window by sliding it (don’t unscrew it).  Then remove underneath gray cover.  On the other end of the micrometer, there is a locking system.  Leave the red clip on.  Remove the small metal piece while holding the micrometer numbers so they don’t move. 

Read More… from Transferpette Adjustment Knob Installation, Item # BT 9481

Top 10 Crimes Committed Against Pipettes

How to NOT use a pipette: #1: Not Proactively Replacing Common Parts at Routinely Scheduled Intervals: Pipettes must have common parts replaced routinely. The following pipette parts should be inspected, tested, and replaced proactively in order to maintain good accuracy and precision. Seal and o-ring: The internal polyethylene seal begins to wear and needs replacing

Read More… from Top 10 Crimes Committed Against Pipettes

Gilson Pipetman L Calibration Tool, Item # 28888

Instructions to use the Pipetman L Calibration Tool. Link to product page: 28888 This tool is for increasing or decreasing the pick-up volume during the calibration process.  Review and follow the Gilson publication, Verification Procedure for Accuracy and Precision.  Contact Us for a copy. Be sure that the sealing system of the pipette (piston, tip

Read More… from Gilson Pipetman L Calibration Tool, Item # 28888

Pipet-Lite, XLS, XLS+ Calibration Tool, Item # RA CT-2

Pipet-Lite, XLS, XLS+ Calibration Instructions: Printable Calibration LogPrintable Calibration Stickers (for use with Avery 5960 labels) Link to product page: RA CT-2 Compatible with: This tool is used for increasing or decreasing the pick-up volume during the calibration process. Review and follow the Rainin publication AB-15, Procedure for Evaluating Accuracy and Precision of Rainin Pipettes. Contact

Read More… from Pipet-Lite, XLS, XLS+ Calibration Tool, Item # RA CT-2

Pipetman Calibration Wrench, Item # 27777

Pipetman Calibration Instructions: Printable Calibration LogPrintable Calibration Stickers (for use with Avery 5960 labels) Link to product page: 27777 This wrench is used for increasing or decreasing the pick-up volume during the calibration process on Pipetman versions that have 6 holes on the top of the Calibration Screw.  Review and follow the Gilson publication, Verification Procedure

Read More… from Pipetman Calibration Wrench, Item # 27777

Pipette Parts – Life Span, Life Cycle, and Performance

The life span of pipette parts may vary based on the: Frequency of pipette use, and if used by multiple personnel Types of liquids aspirated and dispensed Storage conditions when not in use Frequency of preventive maintenance and calibration service There are five (5) common pipette parts/components that attribute to ~95% of all performance issues.

Read More… from Pipette Parts – Life Span, Life Cycle, and Performance